Managed Services
Managed services / PCS
PCS
Panel Client Software

Key Features
Panel Client Software (PCS) is a virtual modem application that enables remote access to alarm panels using wireless (4G) or a hardwired (Ethernet) connection. PCS is a direct replacement for the traditional phone line & modem that is normally required to gain remote access to program alarm panels.
The alarm panel must be connected to a PM45v3, PM1048, PM35, PM54v1, PM54v2 communicator. Technicians can then remotely Upload / Download to compatible alarm panels. PCS also supports generic BELL-103, ITU-V21, ITU-V22 and ITU-V22B modem strings.
- No telephone line required
- Automatic upgrade notifications
- Dynamic user display indicating connection status
- No public IP addresses required
- Upload / Download with 4G
- ‘Atlas’ login icon
Supported Panels
- Bosch: Solution 844 / 880 /16 / 16i / 16+ /64 / 6000 / - (2000 & 3000 must use a PM 54 device)
- Crow: Runner 8 / 16
- DAS: NX4 / NX16 / DL150 / DL250 / DL300 / R128
- Digiflex: Vision 16 / 64
- DSC: PC4020 / PC1616 / PC1864 / PC5020
- Honeywell: V12 / V48 / v50 / v120 (Must use PM1048 with a IFM-H module)
- ICT: Protege' LE
- InnerRange: Concept 2000 / 3000 / 4000
- MCM: Icon8
- NESS: D8 / M1 Gold
- Paradox: MG-5050 / EVO-192 / SP4000
- Risco LightSYS
- Tecom: V8 & V10
- Texecom: Premier Elite 24 v4
- User Defined: BELL-103 / ITU-V21 / ITU-V22 and ITU-V22B
Specification
Communicator: PM45-4GRemote Configuration:
Atlas web portal
Dimensions:
AES Encryption
Operating Environment:
0° - 50° @ 15% to 85% humidity (non condensing)
Supported Modulation:
BELL-103, ITU-V21 / V22 / V22B
System Requirements for PCS
Supported Operating System:
Windows XP or later
Minimum RAM:
1GB
Processor:
1GHz or faster
Required Hard Disk Space:
10MB
Audio Output:
Optional sound card
Communication Protocol:
TCP/IP
Data Security:
AES Encryption